Fogging, ozone or VHP decontamination – what’s the difference?

When looking for room disinfection, you will come across fogging, ozone treatment and fumigation. The names sound similar, but their efficacy and the risk to equipment are completely different. Here we explain the differences.

Fog is not gas

Foggers spray droplets of a solution (aerosol, “dry fog”, micro-aerosol). The droplets fall under gravity, have difficulty reaching gaps and hard-to-reach places, and settle on surfaces. VHP fills the entire room volume evenly, including the inside of cabinets and equipment.

In a study published in Infection Control and Hospital Epidemiology, aerosol systems failed to inactivate half of the biological indicators, while a hydrogen peroxide vapor system inactivated all of them.

Fog droplet vs gas molecule – why gas reaches everywhere

no contactno contact

Fog (fogging, micro-aerosol)

droplet: up to approx. 10 µm

  • Droplets fall under gravity and settle mainly on horizontal surfaces.
  • They spread unevenly and do not reach under equipment, into gaps or inside instruments.
  • The condensate can be more concentrated than the original solution, which risks corrosion of materials.
full contact

Gas (VHP, dry process)

hydrogen peroxide molecule: approx. 0.0003 µm

  • Molecules spread evenly throughout the room volume.
  • Equal contact with all surfaces – horizontal, vertical and curved, including gaps and the inside of instruments.
  • Concentration below the dew point – no condensation on equipment.

Scale: a fog droplet can be up to 30,000 times larger than a gas molecule. If a hydrogen peroxide molecule were the size of a grain of sand (0.3 mm), a fog droplet would be about 10 meters across.

Fog and gas behavior described on the basis of: P. Kačer et al., “Vapor Phase Hydrogen Peroxide – Method for Decontamination of Surfaces and Working Areas from Organic Pollutants”, InTech, 2012.

Additives in fogging products

Fogging products often contain 1 to 20% hydrogen peroxide plus additives such as silver nitrate, peracetic acid or phosphoric acid. These substances can remain on surfaces and equipment. In VHP technology the only active substance is 35% or 59% hydrogen peroxide, which breaks down into water and oxygen. Cheaper technologies, such as foggers, typically use solutions below 9%.

Ozone treatment

Ozone is a strong oxidizer, but it is difficult to control in large volumes and many materials tolerate it poorly. In an evaluation of methods for the European Space Agency, ozone scored 29 points for large rooms, while STERIS VHP technology scored 71.

That is why ozone treatment is a poor choice for professional decontamination. Ozone does kill microorganisms, but only at very high concentrations, with long exposure times and high humidity. In an assessment by Denmark’s Statens Serum Institut, an ozone generator met the requirements of EN 17272 against bacteria at about 135 ppm for 4 hours at 85% humidity, and against bacterial spores only at 350 ppm for 12 hours. Cheap ozone generators produce ozone from the room air, and ozone decomposes quickly and reacts with surfaces. In a Polish study (in Polish) under real-world conditions, such devices reached concentrations below 1 ppm – hundreds of times too low. During typical ozone treatment nobody measures the concentration or humidity either, so there is no way of knowing whether disinfection took place at all. Sterilization is out of the question.

The US EPA reaches the same conclusions in its publication on ozone generators. At concentrations that are safe for people, ozone does not effectively remove viruses, bacteria or mold – decontamination would require concentrations 5–10 times higher than the limits. Even at high concentrations, ozone may not act on microorganisms in porous materials such as ceiling tiles or duct insulation. The EPA also warns against marketing terms such as “energized oxygen” or “pure air”, which suggest that ozone is a healthy form of oxygen. Ozone is a toxic gas with properties completely different from the oxygen we breathe.

Is ozone treatment harmful?

Ozone is also harmful to people. According to the US EPA, inhaled ozone damages the lungs, irritates the airways and worsens asthma symptoms. Indoors it reacts with organic substances from materials and cleaning products, forming formaldehyde among other compounds – which the International Agency for Research on Cancer (IARC) classifies as carcinogenic. Hydrogen peroxide breaks down into water and oxygen and does not form such by-products. Because of the harmfulness of ozone, California became the first US state to ban, from 2010, the sale of indoor air cleaning devices that emit ozone above 0.05 ppm. In practice this means a ban on selling ozone generators for rooms occupied by people.

Does ozone damage equipment and materials?

Yes. According to the EPA, ozone damages rubber, electrical wire insulation, fabrics, dyes and pigments, and it also harms plants. In a laboratory this means a risk to seals, wiring and instruments; in vehicles and helicopters, to seals and electrical systems. The EPA also notes that little is known about the by-products ozone leaves in a room after the process has ended.

Hydrogen peroxide vapor is compatible with most materials used in cleanrooms, laboratories and instruments, and after the process it breaks down into water and oxygen. Materials that absorb hydrogen peroxide, such as paper and other cellulose products, are discussed with the client before the process.

Comparison of decontamination methods

MethodSpectrum of activityMaterial compatibilityEase of useCycle timeValidationSafety and environment
VHP hydrogen peroxide (gas, dry process)highhighhighmediumeasyhigh
Hydrogen peroxide fog (micro-aerosol)highmediummediumshortlowmedium
Ozonehighlowlowmediummediumlow
Chlorine dioxidehighpoorlowlongmediumlow
Peracetic acidhighpoorlowmediumdifficultlow
Formaldehyde (carcinogenic)mediumlowdifficultlongdifficultpoor

high, favorable medium low, unfavorable

When the cheaper method ends up costing more

Ineffective disinfection means a risk of recontamination, a failed audit, production downtime and extra costs. Damaged laboratory instruments or medical equipment cost many times more than the service itself. In hospitals, the cost of hospital-acquired infections in Poland has been estimated at over PLN 800 million a year (Polish Society of Hospital Infections).

Fogger or decontamination service?

Many hospitals, laboratories and plants consider buying a fogger or their own room decontamination unit. Before you decide, compare three options:

  • Buying a fogger. Lower equipment cost, but the fog settles unevenly and does not reach gaps or the inside of instruments. Add to that consumables, training and responsibility for the efficacy of the treatment.
  • Buying a hydrogen peroxide vapor generator. The highest efficacy, but a cost of several hundred thousand złoty, plus servicing, cycle validation and trained operators.
  • A decontamination service. The highest efficacy with no investment: you pay for the completed treatment, and we take care of the whole job at a time that suits you. You have our experienced team at your disposal and receive a report with concentration and humidity graphs.

If you need decontamination a few times a year, a service is usually the simplest and cheapest solution. Request a quote.

Why we don’t use fogging

Since 2009 we have worked exclusively with hydrogen peroxide vapor technology. We don’t use ozone generators, foggers, hydrogen peroxide with silver or H2O2 micro-aerosol. If you’re looking for fogging, talk to us – we’ll advise whether a cheaper method is enough for your facility or whether VHP decontamination is needed.