What is VHP
Hydrogen peroxide vapor technology was developed in the 1980s by the US company STERIS (formerly AMSCO) and registered by the EPA in 1985. Since the 1990s it has been the standard for decontaminating cleanrooms, production lines and quality control laboratories in the pharmaceutical industry. In the gas phase, hydrogen peroxide acts faster and at a lower concentration than in liquid form. We work with 35% and 59% hydrogen peroxide. Cheaper technologies typically use solutions below 9%. The treatment is also known as bio-decontamination, fumigation or room gassing.
How a VHP cycle works
- Dehumidification. We lower the relative humidity of the air, typically to 30–40%, so that more vapor can be held below the dew point.
- Conditioning. We rapidly introduce hydrogen peroxide vapor until a sporicidal concentration is reached.
- Decontamination. We maintain a constant concentration for the planned time; sensors measure temperature, humidity and H2O2 concentration.
- Aeration. Hydrogen peroxide vapor breaks down on its own into water and oxygen. Running the ventilation or any other airflow speeds up the breakdown.
The process runs in a closed air loop through a HEPA filter and is fully automated; all parameters are logged every 5 seconds and presented in the final report.
Efficacy can be verified with chemical indicators and biological indicators carrying Geobacillus stearothermophilus spores. After every cycle we provide a detailed report with hydrogen peroxide concentration and humidity graphs. A cycle is considered effective when the required concentration is reached and maintained for the required time.
The dry process – why it matters for equipment
When the hydrogen peroxide concentration exceeds the dew point, the vapor condenses on surfaces as a concentrated liquid. “Wet” methods deliberately allow this, and condensed hydrogen peroxide can damage electronics, embrittle PVC and discolor steel. In the dry VHP process we keep the concentration below the dew point throughout the cycle.
A comparative study by the National Veterinary Research Institute in Puławy, Poland (Medycyna Weterynaryjna, 2011) found that with the wet method hydrogen peroxide condensed on windows at a temperature difference of only 1.5–1.8°C, and paint chipping was observed in the laboratory. With the dry method no condensation was observed, and the computer and other equipment worked flawlessly.
Efficacy confirmed by research
- Bacterial spores. Greater than 6-log reduction of Geobacillus stearothermophilus spores, even in the presence of 50% whole blood (Applied Biosafety, 2005).
- Anthrax. After the decontamination of GSA Building 410 in Washington, 100% of samples were free of anthrax; the building was cleared for reoccupation.
- Tuberculosis. VHP fumigation sterilized samples of Mycobacterium tuberculosis (Max Planck Institute, 2005).
- MRSA. The UK HPA Rapid Review Panel recommended VHP for fumigating clinical and pharmaceutical rooms, including those with complex electrical equipment (2005).
- Prions. VHP alone reduced prion infectivity by approximately 4.5 log while remaining compatible with electronics (The Lancet, 2004).
- Animal viruses. Inactivation of avian influenza and African swine fever viruses, among others, without damaging equipment (Canadian Food Inspection Agency, 1997).
Spectrum of activity and efficacy standards
Microorganisms differ in their resistance to biocides. The hardest to destroy are prions and bacterial spores, followed by mycobacteria, small non-enveloped viruses, fungi, vegetative bacteria and enveloped viruses. A process that destroys spores eliminates the less resistant groups with a margin to spare. That is why VHP efficacy is verified with biological indicators carrying Geobacillus stearothermophilus spores (typically 106) – the validation standard in the pharmaceutical industry.
| Microorganism group | Examples | Resistance |
|---|---|---|
| Bacterial spores | Geobacillus stearothermophilus, Bacillus anthracis, Clostridioides difficile | highest |
| Mycobacteria | Mycobacterium tuberculosis, M. terrae | high |
| Non-enveloped viruses | norovirus, adenovirus, rotavirus, poliovirus | moderately high |
| Fungi and molds | Aspergillus brasiliensis, Candida albicans, Candida auris | moderate |
| Vegetative bacteria | MRSA, Pseudomonas aeruginosa, Klebsiella pneumoniae, E. coli, Listeria, Salmonella | low |
| Enveloped viruses | SARS-CoV-2, influenza viruses (H1N1, H5N1), HBV, HIV | lowest |
For automated airborne room disinfection processes (fumigation, VHP, fogging), the relevant standard is EN 17272. Standards such as EN 1040, EN 1276 or EN 13624 are suspension tests for liquid products – they describe how the product itself performs in a test tube, not how the process performs in a room. When asking a contractor about efficacy, ask how they will verify it in your facility. More in our comparison of decontamination methods.
Safe for electronics and equipment
The US EPA monitored computers, monitors, phones and other devices fumigated with hydrogen peroxide for 12 months and found no visual or functional changes. By comparison, chlorine dioxide caused corrosion of metal components inside computers (EPA/600/R-10/169 report, 2010, PDF).
Safe for people and the environment
In many laboratories, VHP has replaced formaldehyde, which is carcinogenic, deposits on surfaces as paraformaldehyde and requires lengthy cleanup. Hydrogen peroxide breaks down into water and oxygen, and the room can be used safely after aeration.
Want to compare VHP with fogging or ozone? See VHP vs fogging and ozone.